ini, where nnnn is the. Check. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 50dBA are also limit of acoustic emissions for creative headwork given by norms and law in our country. Opens in a new window or tab. Find many great new & used options and get the best deals for (1) National Instruments NI PXI-8106 Dual-Core Controller with NI PXI-1002 P/S at the best online prices at eBay! Free shipping for many products!Test Panel does not work with the PXI-6541/6542/6551 in PXI-1002. Loading. 7000-18021-2160300 Sensors & Switches from MURR ELEKTRONIK In Stock, Order Now! Same Day Shipping, 2-Year Warranty - CONNECTOR, MSUD VALVE PLUG, FORM A, 18 MM, PVC JACKET, AWG18 CABLE SIZE, GRAY COLOR, 3 M, 24 VAC/VDC OPERATING. 3 mm x 100 mm without face plate • 1 RS-232 console port • Card reset IndustryPACK (IPACK) Modules The PXI-400 is complemented by a wide range of IPACK modules available from MAX Technologies supporting Analog, Discrete, Serial ASYNC RS-232/422/485, HDLC/SDLC, MIL-STD. Search for used 1002. National Instruments PXI-1002 745749-01 w/PXI-8156B,6040E. These platforms are used as a basis for building electronic test equipment, automation systems, and modular laboratory instruments. 2. Its compact and lightweight form factor is ideal for minimizing the footprint of your installation, making it ideal for desktop or portable use cases. The shared PCI or PCI Express bus enables faster data throughput and lower latency than box instruments can achieve, while integrated timing and synchronization signals help users. $224. 0 in. item 7 National Instruments NI PXI-1042 Cards embedded controller 8101 8231 4220 National Instruments NI PXI-1042 Cards embedded controller 8101 8231 4220. 10 shipping. ). 硬體: PXI/CompactPCI>>Chassis>>PXI-1002 問題: 我想要由 slot 2 的設備來提供 10 MHZ 之參考時脈, PXI_CLK10. 0 Kudos Message 5 of 5I am using the PXI-8175 embedded controller which has an external SMB trigger connection. Backplane National Instruments general-purpose PXI chassis backplanesI have a Labview RT system configured on a PXI-8045RT embedded controller, mounted on a PXI-1002 chassis. platform. NI-XNET I want to establish CAN FD communication using the Automotive Diagnostic Command Set Toolkit (ADCS) and an NI-XNET CAN interface. This just recently came up. Comment fait-on dans un. PXI-1006. 50 W. The National Instruments PXI-1002 is a general purpose PXI chassis that provides platform options to meet measurement and automation application needs. The operational range of the current configuration is up to 1 GHz (40 mT), w. When i run both above vi one after one they work fine. 5 to upgrade a Windows system that serves as a host for one or more LabVIEW Real-Time Module targets, it is highly recommended that you also update your targets to leverage. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100Is it possible to route signals of relaxation between two chassis PXI-1002 with the PXI-8335? Hello. 7. . View More. PXI-1002 chassis; PXI-1006 chassis; PXI-1010 chassis; PXI-1011 chassis; PXI-1020 chassis; PXI-1025 chassis; PXI-8150 controller; PXI-8150B. Chad, Thanks for your reply. used National Instruments NI PXI-6509 Input/Output (DIO) device. The software is Labview 2010 sp1 and the NIScope 380 drivers. Tektronix is the nation's leading provider of multi-brand calibration services. 0, PXI-1002 chassis, Processor PXI-8156b. 如果您仍想运行双系统,建议您更换控制器的物理硬盘驱动器以. PXI-1002 PXI-1006 PXI-1010 PXI-1011 PXI-1020. PXI is based on industry-standard computer buses and permits flexibility in building equipment. The LED blinking is documented in the PXI-8140RT Series User Manual on page B-1. Options. Release Notes. 50 W. 000 documents to find the user guide you are looking for. ARCHIVED NI 8350 USER MANUAL AND. The new electronics consists of a National Instruments (NI) PXI‐1002 chassis that contains a PXI‐8176 controller, a PXI‐5112 100‐MS/s digitizer, and a PXI‐6602 scalar and digital I/O module. I am also running the position measurement vi to acquire the rotary encoder motion using PXI-6602. I am using Labview 8. Agilent 34401A. NIが設計するシャーシはこうした要件を上回っており、各スロット. Overview. Note: To facilitate power supply and module. PXI Platform Services provides support for customers using NI PXI and PXI Express chassis and controllers. A PXI-1002 module that provides a single inter face to a computer while storing many LabVIEW boards. My speed is a PWM signal which I recently rewired through the counter 0 of. Stock # 57621-1 . Allow to dry before reinstalling filter, panel, feet, and screws. """Operation that can be performed on the REN line. PXI-1000B (DC option) 24 W (2 A draw off 12 V battery) PXI-1002. Page 30 Disconnect the power cable from the power supply on the back of the chassis. 1. SPONSORED ^^ NATIONAL INSTRUMENT NI PXI-1042 CHASSIS (LNC50) $300. National Instruments NI PXI-1002. used. Buy Surplus As Low As. . It includes the definition of the PXI 10 MHz system clock, which is distributed to all peripheral modules in a system. 0 specification Input voltage: 90 to 264 VAC universal Input frequency: 47 to 63. I have one module installed in the chassis which is a. 0 in. 3U PXI chassis that forms the basis for low-cost PXI systems. My input is a +/- 100 mv sinusoidal signal. $1,449. The VXI interface is associated with a VXI controller that you install in slot 0 of a VXI chassis. PXIe, 10-Slot (7 Hybrid Slots, 1 PXI Express System Timing Slot, 1 Peripheral Expansion Slot), Up to 24 GB/s PXI Chassis The PXIe-1092 features a high-bandwidth backplane. 새시에서의 소비전력을 정확하게 계산하기 위해서는 새시가 비어있을때 쓰는 전력량을 신경쓸 필요가 있습니다. Whenever we run Cal Exec, the system crashes/reboots, and it appears to be due to running out of RAM. as the subject says, I am interested in the delivery of a signal to trigger between two chassis PXI-1002. From the popup menu select PXI Chassis and click Next. Using a Phillips screwdriver, remove the screws. Not a member? Sign up today to enjoy Radwell price on new product, surplus, and repairs. 0. 00 Repair Yours. The new PXI-1006 is the ideal platform for high-module-count, high-performance applications. The PXIe‑1071 is designed for a wide range of test and measurement applications and provides a high-bandwidth backplane. 0 & RT 7. NI Employee (retired) 03-23-2009 03:48 PM. vxi-mxi-2 termination VXI and VME. Next expand the menu so that you can choose the appropriate PXI Bus for your application. PXI-6052E PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, MULTIFUNCTION I/O MODULE 16INPUT 16BITS. Overview. Hi, I was wondering if I could use a SH68-68-EPM cable to connect a PXI-6704 (sitting in a PXI-1002 Chassis and talking to my (Windows 7) PC via a PCI-8331) with a BNC-2090-box. Release Notes. The PXI-1002 4-slot chassis is the ideal platform for low-cost, compact PXI systems. Expand the NI-DAQmx SCXI Chassis section and choose your chassis model and click Finish. Be the first to write a review. PXI 8176 Crashes When Running Cal Executive 3. A virtual instrument was programmed in LabVIEW in order to synchronize and save the data and images. We offer repair services with a 1 week turnaround and calibration services with a 2 week turnaround. Ensure that the ejector handle is in the downward (unlatched) position. The PXI-6040E and PXI-4060 both come up right away in the configuration. 75 eBay determines this price through a machine learned model of the product's sale prices within the last 90 days. Order international: +1 609. Through the IN connector,Call 800. Hello, How can I get information with LabView about the PXI digitizer I am using, like its name (e. Open a service request. 5. National Instruments PXI-8196. The VOA Series is a MEMS-based variable optical attenuator with fast attenuation speed, low insertion loss and in-built power meter. This system is particularly designed for researchers who need more. Have in the three available slots (left to right) PXI-6551, PXI-6542 and PXI-6541. PXI-1000, PXI-1002, PXI-1006, PXI-1010, etc. or Best Offer. The software is Labview 2010 sp1 and 380 NIScope. Solution. P. I am not aware of a 2 or 3 slot chassis; however, there are a couple of resources you could use to help locate one. All of your software and drivers will be installed on the desktop PC. 10. Any ideas on the cause? Any ideas on the fix? Would appreciate your help, HunterNational Instruments PXI-1002 4 Slot. PXI-8184, PXI-8185 RS-232 PXI-8184 PXI-8185 IEC-60082-2-2 PXI-1002 778658-01 intel 8185 PXI-1042 PXI-1045 778469-512 8184 PXI-1006 ps2 connector: 1997 - RS170 Module. PXIe, 10-Slot (7 Hybrid Slots, 1 PXI Express System Timing Slot, 1 Peripheral Expansion Slot), Up to 24 GB/s PXI Chassis. EN. 1. Get the best deals on PXI & VXI Controllers when you shop the largest online selection at eBay. 00. PXI Platform Services provides support for customers using NI PXI and PXI Express chassis and controllers. Page 41 To connect both a PS/2 keyboard and PS/2 mouse to the NI PXI-8184/8185, use the Y-splitter adapter cable included with your controller (refer to Figure 4-1, Y-Splitter Cable). . Hi, I was wondering if I could use a SH68-68-EPM cable to connect a PXI-6704 (sitting in a PXI-1002 Chassis and talking to my (Windows 7) PC via a PCI-8331) with a BNC-2090-box. Best Regards, Jeremy R. AEJ. A PXIe. When I switched back to an old PXI-1002 chassis (4 slot), things work fine. 0f0. As mentioned in the National Instruments PXI Chassis Part 1 Blog Post, NI PXI Chassis have many beneficial features. Replacement Y-splitter cables are available from National Instruments, part number 778713-01. 而且具有良好的通用性、扩展性,通过适当增加部分硬件 接口 和编制相应的软件就能实现其他型号瞄准. If more bandwidth is needed, consider upgrading to PXIe. NI PXI-1006 Visio Stencil-EQID=NATI007. 0. Turn on suggestions. The subcarrier assignment is defined by ITU standard G. FTDI VCP Driver 2. Newport RT Series. For the highest performance system, configure one of Keysight's Gen 3 chassis with either the M9023A or M9024A PXIe high-performance system modules. 0. Manufacturer: ETS This listing contains affiliate links. Stock # 57530-1 . Pxi 1002 Manual, Lc-26sb14u Owners Manual, 1994 Sable Service Manual, Getrag 360 Manual, Qa Qc Manual Examples, Zyxel 5001z Manual, Manual Removal Of. 1. 0. national instruments ni pxi-1002 745749-001 4 slot chassis working ***this item is used. Find many great new & used options and get the best deals for National Instruments Pxi-1002 4 Slot Chassis V04x410e3 at the best online prices at eBay! Free shipping for many products!. I recommend you fill this gap with a filler panel if you have not already. 1. 1 to upgrade a Windows system that serves as a host for one or more LabVIEW Real-Time Module targets, it is highly recommended that you also update your targets to leverage. If the NI-DAQmx connected to the USB is running buffer collection or is accidentally terminated when generating tasks, it may cause the system to crash, and the computer will restart or display the Windows Kernel panic check (that is, the blue screen for crashes). A valid service agreement may be required. View More. This chassis accommodates the controller and various I/O modules for control and measurement options. NATIONAL INSTRUMENTS NI PXI-1031 CHASSIS With PXI-8105 , PXI-6251 and PXI-4220. The PXI-1002 4-slot chassis is the ideal platform for low-cost, compact PXI systems. If you need a specific firmware or series relating to PXI-1002, we probably have it. Object has no attribute 'parameters' - Hugging Face Forums. alvin1462 (3,555) 100%. Add to Cart. Release Notes. 1. I cannot get it to work for the life of me. When I use "AI SingleScan. 1 that shows me how to route signals in or out of the trigger connection? I am unsure how it operates, any additional information about its. 5. Stock # 58167-1 . Opens in a new window or tab. Clamp MEAs. 2)and running the same on PXI-RT-OS. If I exit without closing the RT Engine VI's the program runs for longer time and later. 4+16-channel Mixed Signal Oscilloscope. In which there are 2 chassis, (1) PXI 1002 with PXI8176 controller with RT, PXI 6071E DAQ card (2) SCXI 1001 with SCXI 1125 card and SCXI1327 block. Distributors: Part: Package: Stock: Lead Time: Min Order Qty: 1: 10: 100: 1,000: 10,000Get a quote for a Used PXI 1002 Miscellaneous Test Equipment from Apex Waves, LLC at used-line. If it is confirmed to be a module issue, follow the steps outlined in DAQ Device or Module Does Not Appear in LabVIEW And/Or MAX. 201600147 PubMed 27166612 Included in kit: EasyClone-MarkerFree Vector Set Related items: From this. 6. This unit is sealed in the original manufacturers packaging. 8. PXI is based on industry. Re: what is the diiference between pxi-1002 and pxi-1031. I also have PXI-6025E in slot 3, and 6527 in slot 4. 关键在于了解PXI的组成架构及其如何匹配商用PC技术: PXI机箱与台式机机箱的对比 PXI控. or Best OfferThe PXIe or PXI chassis being an extension cannot function on its own as it has no brain. PXI Chassis. Re: what is the diiference between pxi-1002 and pxi-1031. PXI-8105 Visio Stencil-EQID=NATI065. This versatile model (Part. The files are of the form pxisys_nnnn. Keysight offers a variety of PXI chassis with different sizes and performance characteristics. So I want to be able to see a difference of 1/3 amp over a roughly two amp range. In NI Measurement & Automation Explorer (MAX), you can use VISA Test Panels to view the PXI backplane for physical hardware. 1. The PXIe or PXI chassis being an extension cannot function on its own as it has no brain. . TescomAustin. PXI-1002샤시는 가장 저렴한 샤시 옵션입니다. According to the information given previously in this thread this. Automotive Diagnostic Command Set Toolkit Driver. 0 R 3. PXI机箱上的电源开关有两个选项,“On”和“Standby”。其中的“Standby”是什么意思?In NI Measurement & Automation Explorer (MAX), you can use VISA Test Panels to view the PXI backplane for physical hardware. NI VISA 5. Pickering's PCI switch and simulation cards are built using the same basic technology as their PXI cards and utilize the same software drivers, soft. It says: The USER1 LED indicates LabVIEW RT status: • If this LED blinks one time every 2–3 seconds, the IP address is 0. National Instruments general-purpose PXI chassis, PXI-1000B, PXI-1002, and PXI-1006 Ð provide you with platform options to meet your measurement and automation application needs. But when I attempt. National Instruments estimates empty chassis power draw for the following chassis: Empty Chassis Power Draw Values for PXI (e) PXI-1000B. 50 in. View More. PXI-1002 Data acquisition card PXI-1002 Data acquisition card Module Clips Drive controller servo motor Contact: Mr. National Instruments PXI-1000 with 3U sized backplane and 8 slots: Call: PXI-1000B: National Instruments PXI-1000B Chassis- 47 to 63 Hz input frequency: In Stock Ships in 5-10 Days: PXI-1002: National Instruments PXI-1002- 170 W power supply: In Stock Ships Today: PXI-1006: National Instruments PXI-1006 Chassis- 600 W maximum power: In Stock. PXI Expressの仕様では、各周辺スロットで少なくとも30 Wの電力が利用でき、各スロットで同じ量の熱を放散可能なことを要件としています。. MXI-3最適化用アプリケーションはナショナルインスツルメンツのあらゆるPXIシャーシに関連する pxisys. If you are using PXI Platform Services 18. オープンな業界規格であるPXIは、60社を超える計測器ベンダがおよそ1,500種類の. DSM also incorporated an enclosure in the system’s structure to protect the stepper motor drives and two NI UMI-7764 Universal Motion Interfaces. At present, these two chassis are connected by a MXI - 3 system using maps PXI-8335. Hello, I try to initialize my PXI-1002 chassis, with a PCI-MXI-3 in my computer. It would be helpful if there was one way to start the chassis after the PC is booted. Getting Started with Your PXI-1002 - National Instruments. This interface, along with the other relevant hardware, is shown below. packaging. National Instruments PXI-1031. 若使用此方式,NI对PXIe控制器的任何故障概不负责。. When this PXI-8106 is placed in a PXI-1002 chasis, the boot process proceeds as normal with no errors. This week I had the same problem. . 2 mm) from air inlets and outlets. 10 shipping. The NI PXI-1052 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, a s evidenced by receipts or other documentation. " -Martin E. Can anyone help me set this up? My device descriptor I think it should be is PXI3::3::INSTR but I have no idea. 00. This chassis incorporates all features defined by the PXI and CompactPCI specifications including: integrated cooling, a rugged modular construction, and high-performance backplane with. 85 Expedited. LabVIEW Real-Time 11. Create an Accountplatform. I would like to download the 7. I still having questions. ini file. 32 to 64 Channel Converter. ガイドの「ni pxi-8101/8102 が起動しない場合」セクションを参照 してください。 図2 は、ni pxi-1036 シャーシのシステムコントローラスロットに取り付 けたni pxi-8101 コントローラを示しています。 pxi デバイスは他のどの スロットにも取り付けることができます。 Tearing my hair out trying to get Test Panel to work with system as described below: PXI-1002 Chassis with PXI-8176 Controller. This chassis is ideal for engineers and scientists who need a PXI chassis with reduced acoustic noise emissions for office, laboratory, and educational environments. ini ファイルを探し当てます。 The NI PXI-8186/8187 embedded PXI computers are warranted against defects in materials and wor kmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. CCD Camera. I hope this helps. 00. 2 (rated by 11 users) Compatible devices: FRAC-100, SCXI-1141, SGA-5RT, S180, IMAQ PCI-1409, MagCore Plus II, NI DIDS-2103, IMAQ PXI-1409. 而不是使用內建於 PXI 機箱的 10 MHZ 時脈. I am able to connect PXI in MAX 4. This includes modular instruments, such as oscilloscopes and digital multimeters. Shipping: $106. National Instruments, PCI-7342, Motion Controller Board, New. NI-VISA. Hello, I am using buffered continuous handshake input vi to acquire the digital data using PXI-6534. is pxi-1002 vulnerable from virus attack and what can we use to prevent this (Norton used company wide)Overview. The NI PXI-1002 incorporates all features. The files are of the form pxisys_nnnn. I configure my board to acquire at 64 MSmpl/sec with digital trigerring. Support for LabVIEW 8. Get Started with VXI and PXI Interfaces. Our PC is Dell precision 340 (pentium 4) with Windows 2000. The mechanical features are identical between the PXI-1042 and the PXI-1042Q chassis unless otherwise noted. . In the three places available (from left to right) PXI-6551, PXI-6542 and PXI-6541. LabVIEW Run-Time 11. I'm trying to use the IVIDmm activex control to control the DMM. I would like to ask if you know some effective solution: - hand-made silencer box - cheap silencer box. I have a PXI 1002 with a 6025E I/O card, and I want to monitor the current level of some AC going into a set of heaters, to see if any of them are not powering up. The signal was collected with a PXI-1002 collector from National Instruments (Scientific Consulting, St. Download scientific diagram | A PXI-1002 module that provides a single interface to a computer while storing many LabVIEW boards. . Agilent 33120A. 该图片将PXI系统的机箱、控制器及PXI (e)外围模块与商用台式机组件进行了比较。. #: 2-wire DTR mode controlled with echo. used, working, good condition with some signs of use such as small scuffs or marks. A thorough and up-to-date guide to putting positive psychology into practice From the Foreword: "This volume is the cutting edge of positive psychology and the emblem of its future. 1 and earlier are not available online. ini file. We have the max RAM of 512 MB installed. 我有一个pxi-1002(带有控制器)与pxi-1011通过mxi-3相连接。我要使用pxi-1011的scxi部分,所以需要使用下面的pxisys文件。我用mxi-3成功控制了scxi部分,我是否有办法更改max以使pxi-1011的其他器件以及4槽的器件不显示为0槽?A collection of manuals for home computers. 09-11-2014 05:38 AM. This chassis incorporates all features defined by the PXI and CompactPCI specifications including: integrated cooling, a rugged modular construction, and high-performance backplane with. At GimmeManuals we collect popular and hard to find owner’s manuals and then archive them in an easy-to-search way. This means that the PC is the brain of the operation and this chassis is just an extension. My speed is a PWM signal which I recently rewired through the counter 0 of my board. It. Each heater pulls 0. Different electrodes are suitable for various experimental scenarios. PXI 1002 chasis PXI 8175 controller PXI 6025E DAQ card PXI 5152 scope PXI 6602 counter timer. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. National Instruments NI PXI-1031 . These chassis incorporate all features defined by the PXI and CompactPCI specifications, including a rugged, modular construction, integrated IEEE 1101. . I need to run the vi on my laptop and get access to the PXI devices. $61. About This Manual NI PXI-1042 Series User Manual viii ni. Find used analytical, medical, laboratory, dental, biotechnology and test equipment on Machinio. I have a PXI 1002 with a 6025E I/O card, and I want to monitor the current level of some AC going into a set of heaters, to see if any of them are not powering up. NATIONAL INSTRUMENTS NI PXI-1002 745749-001 4 SLOT CHASSIS WORKING. We will do our best and help you provide the solution. Because PXI is an open industry standard, nearly 1,500 products are available from more than 60 different instrument vendors. The VXI interface is supported through a VISA-VXI object. The new computer is running Vista. for PXI and CompactPCI Overview National Instruments general-purpose PXI chassis, PXI-1000B, PXI-1002, and PXI-1006 – provide you with platform options to meet your measurement and automation application needs. 26 W. Stock # 57530-1 . 0 Kudos Message 1 of 2 (3,750 Views) Reply. ). PXI-1002 Controller module, NI, PXI-1002 Controller module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United StatesThe NI PXI-1042 Series User Manual describes the features of the PXI-1042 Series chassis and contains information about configuring the chassis, installing the modules, and operating and using the PXI-1042 Series chassis. NI PXI Expressスロット冷却能力:38 W、58 W、または82 W. My goal is to monitor pressures, flows, temperatures, and speed in one VI. 2. Multifunction I/O NI PXI-6071E . The PXI-1002 4-slot chassis is the ideal platform for low-cost, compact PXI systems. 1 to upgrade a Windows system that serves as a host for one or more LabVIEW Real-Time Module targets, it is highly recommended that you also update your targets to leverage new features and improved performance. I have installed the NI drivers and Measurement and Automation (via NIDAQ880f2). constants. 00. The PXIe/PXI chassis is an extension of the computers' busses, your chassis needs to be on before the computer is on. Re: FTDI Virtual Comm. 10. 10 mechanical packaging. When I change my Vertical Range the binary. 4) Using the chassis model number, locate the corresponding pxisys. Member. NI National Instruments VeriStand 2011 Software. Dans ce chassis je dispose d'une carte Lin NI PXI-8516. The PXI-1002 is a pxi from National Instruments. cancel. In addition to the communication buses, the electrical specification also defines the timing and synchronization capabilities. I am using Measurement and Automation Explorer version 3. The new PXI-1006 is the ideal platform for high-module-count, high. The connection to the host PC is via crossover cable(the host pc is not connected to a network and running with windows 98). 11-17-2020 05:06 AM. We have New & Used PXI-1002 PXI Chassis by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. 2 mm) from air inlets and outlets. used. ^^ National Instruments PXI-1002 Compact PCI with NI PXI-8175 (AY52) $375. I have tried with two different 6713 modules and get exactly the. PXI-1002 5 to 40 ¡C 0 to 50 ¡C PXI-1006 5 to 45 ¡C 0 to 55 ¡C PXI-1010 Not r ecommended 0 to 35 ¡C PXI-1011 5. If you are using PXI Platform Services 18. 5. How important is the orientation of MXI-2 cable VXI and VME. But it doesn't work. The new PXI-1006 is the ideal platform for high-module-count, high-performance applications. ini を含むフォルダを作成します。ご使用のPXIシャーシの型番(例:PXI-1002、PXI-1000B、PXI-1020、PXI-1010など)を決定し該当する pxisys. Additional Features: Low-cost, compact 4-slot chassis 170 W power supply with universal AC input Optional side handle and feet kit for portability Complies with PXI specification Accepts modules compliant with CompactPCI, PICMG 2. I have just moved my PXI-1002, containing a PXI-6070e in slot 3, to a new computer. Find More Solutions. 00. Are you wondering about. Download scientific diagram | Setup for biomaterials laboratory workstation using National Instruments PXI-1002 and LabVIEW software. 50 in. National Instruments NI PXI-6143 . 1002-PXI chassis with controller PXI-8176. NI PXI-1010 Visio Stencil-EQID=NATI015.